Advanced Logic Research Solo 9100 Especificaciones Pagina 85

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 108
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 84
74 Maintaining and Troubleshooting Your E-4200 System
The IDE drive is not recognized by the system.
Memory/Processor problems
Memory errors were detected during system start up.
Probable Cause Solution
The primary IDE
device may be config-
ured incorrectly.
Restart your computer, and then press
F
1
to
enter the setup program. From the
Main
menu, set the
Primary IDE Master
to
Auto Con-
figured
.
The drive may not be
configured properly.
Consult the hard disk user’s guide for
instructions on how to configure the drive.
The drive cables are
not connected prop-
erly.
Open the system and check all cables con-
nected to the controller card.
The drive controller is
not seated properly.
Open the system and reseat the drive con-
troller.
Probable Cause Solution
Memory was added or
removed, and the new
configuration was not
saved in BIOS Setup.
Enter BIOS Setup and save the new mem-
ory configuration.
The memory was
installed incorrectly.
Check the memory for proper seating and
orientation.
A memory chip is
faulty.
Replace the card on which the faulty chip
resides. Third-party diagnostic programs
can help determine which chip or memory
segment is failing.
Vista de pagina 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 107 108

Comentarios a estos manuales

Sin comentarios